<Error>
<ErrorNumber>15621</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: no plate on unload X-axis or low vac, can't continue
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The machine was expecting a plate on the unload x-axis table but it did
not detect one.  To verify that there is a plate on the unload table, the
system polls the vacuum sensor until either vacuum reads higher than
threshold or a timer expires.  If the vacuum is less than the set
threshold then, the system will issue this error.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
</text></DescriptionText>
</OperatorAction>
<Cause>
Verify that the NVS parameter vac_threshold_x for the threshold is set
to the appropriate value
</Cause>
<Cause>
Verify that the suction cups are place at the right location to grab a
plate
</Cause>
<Cause>
Verify that the suction cups are in good condition
</Cause>
<Cause>
There may be a problem with the air pressure system
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:16 2008 PST
</Updated>
<Links>
</Links>
</Error>